The human version (we wrote this, not the council)
This section is Appendix 7, which sets out sustainable parking standards. Table 1 gives residential standards for car parking, cycle storage and electric vehicle charging. For general needs housing, car parking starts at 0.5 spaces per studio unit, 0.75 per 1 bedroom unit and 1 per 2 bedroom unit, rising for larger homes. Long term cycle storage is 1 per bedroom for 1 to 3 bedrooms. Specialist housing and HMOs have their own standards. Table 2 sets non-residential standards, by use, for car parking, cycle parking and charging points.
An unofficial plain English summary. The official wording below is
what counts at examination; check it before you rely on anything here.
What the plan says
The text below is extracted automatically from the official PDF and may
contain artefacts; the PDF is authoritative.
Appendix 7: Sustainable Parking Standards
Table 1 Residential Parking Standards
C3 – Residential units1
Car parking spaces Cycle storage
spaces
Charging Plug in
Points
General Needs
Housing (including
flats and
bungalows)
Curtilage
Communal
Studio 0.5 per unit
1 to 3 bedrooms: 1 per bedroom
long term
4 or more bedrooms: 3 per unit
long term
1 visitor space per 10 units short
term
1 socket/charging
point per house
with private
parking-
Communal
parking - 1 active
charging point per
dwelling unit
Remaining spaces
passive provision
over and above 1
space per unit and
above 10 units
1 bedroom 0.75 per unit
2 bedroom 1 per unit
3 bedroom (flat) 1.5 per unit
3 bedroom (house) 2 per unit 1.5 per unit
4 bedroom 2 per unit
5 bedroom To be determined on a
case-by-case basis 6 + bedroom
Additional parking requirements
HMO 0.5 spaces per bed
1 per bedroom long term
1 socket/charging
point per house
with private
parking or 1
roadside charging
point per house
where private
parking is no
available
Houses with additional
habitable rooms on
upper floors/ roof
space
1 per additional habitable
room2
1 per bedroom long term
Communal parking
1 in 3 active
provisions
Remaining spaces
passive provision
Flats or Bungalows
with a total of 6 or
more habitable rooms
and bedrooms
1 All spaces to be rounded to the nearest whole number in the case of odd numbers (e.g. 1
x 5 bed HMO, 3 spaces, 3 x 1 bed flats, 2 spaces). For general needs housing, additional
visitor parking in larger schemes with communal parking should not exceed 0.2 space per
dwelling with 1 disabled visitor space for every 10 visitor spaces.
2 All rooms over 8 square metres which are not kitchens, utility rooms, bathrooms, WCs or
circulation space are a habitable room. Large habitable rooms or open plan areas,
typically over 25m2 and capable of subdivision will be treated as two habitable rooms.
Parking requirements for additional habitable rooms on upper floors within townhouses or
dwellings with reversed layouts will be considered on their individual merits but will not
typically be sought unless there are three or more additional habitable rooms within the
entire property.
Houses with 5 or more
habitable rooms on the
ground or lower
ground floor
Specialist housing with support or care
Category I –
Retirement dwellings,
no 24-hour warden
control, 1 bedroom
1 per unit
1 per bedroom long term
1 socket/charging
point per unit with
private parking-
1 in 5 spaces active
provision
Remaining spaces
passive provision
1 per 20 units short term
visitor
1 per 20 bedrooms long term
Category I –
Retirement
dwellings, no 24-hour
warden control, 2 or
more bedrooms
1 per unit
Category II –
Supported or extra
care, self-contained
units (with on-site
staff), 1 bedroom
. 0.75 per unit for residents
and visitors, 0.25 per unit
for staff
Category II –
Supported or extra
care self-contained
units (with on-site
staff), 2 or more
bedrooms
1 per unit for residents and
visitors, 0.25 per unit for
staff
Category III – non-
self-contained
specialist housing
including nursing or
care homes
To be determined on a
case-by-case basis
Table 2 Non-Residential Parking Standards3
Unless otherwise stated, floor areas are gross measured externally.
Use Class / Type Required number of
parking spaces (including
visitor spaces unless
otherwise stated)
Minimum cycle parking
standard
Electric
Vehicle
Charging
Points
Class E
Superstores
Large supermarkets
1 space per 20m2
1 s/t space per 100m2 of
floor space
1 l/t space per 200m of
floorspace
1 in 10 spaces active
provision
1 in 4 spaces
passive
provision
Retail
warehouses
Garden
centres
Other retail
uses
1 space per 35 m2
3 FTE = full time equivalent. s/t = short term. l/t = long term
Parking requirements will be rounded up or down to the nearest whole parking space
requirement (e.g. a B8 development of 350m2 would be expected to provide 11 car parking
spaces, rather than 11.25 spaces).
Financial and
professional services
(Banks, building
societies etc.)
1 space per 40 m2 (Town
centres)
1 space per 30 m2
(neighbourhood or local
centres)
1 s/t space per 200 m2
1 l/t space per 200m2
1 in 10 spaces active
provision
1 in 5 passive
provision
(minimum
requirement-
5 spaces)
Restaurants and Cafes 1 space per 5 m2 of public
floorspace
1 s/t space per 100 m2
1 l/t space per 100m2
1 in 10 spaces active
provision
1 in 4 spaces
passive
provision
Offices 1 space per 40m2 1 s/t space per 500 m2
1 l/t space per 200m2
(Office) staff
1 l/t space per 500m2
(Industrial)
1 in 5 spaces active
provision
1 in 2 spaces
passive
provision
Researc
h and
Develop
ment
1 space per 50 m2
Parking provision for lorries
considered on a case-by-
case basis
Light industrial
Film and Television
Production
1 space per 50 m2
Parking provision for
production trucks, trailers
and other ‘on location’
vehicles will be considered
on a case-by-case basis
1 l/t space per 200m2 and
1 s/t space per 1000m2
(for office accommodation
and workshop schemes)
1 l/t space per 500m2
(for sound stages)
1 in 5 spaces active
provision
1 in 2 spaces
passive
provision
Day centres 1 space per 9 m2 or
1 space per 4 visitors plus
1 space per FTE staff
1 s/t space per 200m2
1 l/t space per 200m2
1 in 10 spaces active
provision
1 in 4 spaces
passive
provision
Surgeries and
clinics (including
doctors, dentists
and vets)
1.5 spaces per consulting
room
1 space per FTE non-
consultant staff
Greatest of: 1 per 50m2 or
1 per 30 seats/capacity
1 l/t space per 5 staff
1 in 10 spaces active
provision
1 in 5 spaces
passive
provision
Nursery schools /
playgroups
1 space per 4 pupils
2 l/t space per 10 staff
1in 5 spaces active
provision
1 in 3 spaces
passive
provision
Class B2
General industrial
up to 250
m2 floorspace
5 spaces plus 1 space per
50m2. Parking provision for
lorries considered on a
case-by-case basis
1 s/t space per 1000 m2
1 l/t space per 500m2
1 in 5 spaces active
provision
1 in 2 passive
provision
General industrial
over 250 m2
10 spaces plus 1 space
per 75m2. Parking
provision for lorries is
considered on a case-by-
case basis.
Class B8
Storage or
distribution up to
250 m2 floorspace
1 space per 75m2. Parking
provision for lorries
considered on a case-by-
case basis
1 s/t space per 1000m2
1 l/t space per 500m2
1 in 5 spaces active
provision
1 in 2 spaces
passive
provision
Storage or
distribution over
250 m2 floorspace
10 spaces plus 1 space
per 75m2. Parking
provision for lorries
considered on a case-by-
case basis
Class C1
Hotels and motels5 1 space per bedroom plus
1 space per 3 FTE staff plus
1 space per 5 m2 public
floor space for conference
or exhibition facilities plus
1 coach space per 100
bedrooms (minimum)
1 l/t space per 10 beds
2 l/t space per 10 staff
1 in 5 active
provisions
Remaining
spaces passive
provision
Small hostel (single
parent
or couple with no
children)
0.75 spaces per unit 1 l/t space per 2 units
1 l/t space per unit
Family hostel (two
adults and two
children)
1 space per unit
Class C2
Institutions / homes
with care staff on
premises at all
time1
Please see specialist housing requirements
Supported or other
specialist housing 1,2
Hospitals To be assessed on a case-by-case basis
Education – Halls of
Residence
1 space per 2 FTE staff
plus
1 space per 6 students
1 l/t space per 3 students
1 l/t space per 10 staff
1 in 5 spaces active
provision
remaining
spaces passive
provision
Class F1
Schools
(including
residential)
1 space per FTE staff
plus
1 visitor space per 100
students
Minimum requirement
(based on travel plan
mode share targets)
1 space per 10 students
1 space per 20 staff
1 in 5 spaces active
provision
1 in 3 spaces
passive
provision
Further education 1 space per FTE staff, plus
1 space per 5 full-time
students
1 l/t space per 5 students
1 l/t space per 10 staff
1 in 5 spaces active
provision
1 in 3 spaces
passive
provision
Places of worship 1 space per 10 m2
Greatest of: 1 per 50m2 or
1 per 30 seats capacity
1 in 10 spaces active
provision
1 in 4 spaces
passive
provision
Public halls and places
of assembly
1 space per 9 m2 or
1 space per 3 fixed seats
plus
3 spaces per 4 FTE staff
Greatest of: 1 per 50m2 or
1 per 30 seats capacity
1 in 10 spaces active
provision
1 in 4 spaces
passive
provision
Class F2
Community and family
centres
1 space per 9 m2 plus
1 space per FTE staff
Greatest of: 1 per 50m2 or
1 per 30 seats capacity
1 in 10 spaces active
provision
1 in 4 spaces
passive
provision
Squash courts 2 spaces per court 1 s/t space per 25 2
1 space per 10 staff Gyms and health clubs 1 space per 15 m2 public
floorspace
Ice rink 1 space per 12 m2 rink
area
Ten pin bowling
2 spaces per lane
1 s/t space per 3 lanes
/rink
1 s/t space per 25
spectator seats
1 l/t space per 10 staff
Football pitches 20 spaces per pitch
1 space per 5 paying
spectators (where there is
fixed or temporary seating)
2 s/t space per pitch
1 in 10 active
provisions
1 in 4 passive
provisions
Other outdoor pitches 1 space per 2 users
(maximum potential usage)
1 space per 5 paying
spectators (where there is
fixed or temporary seating)
Golf course 100 spaces plus 50
overflow spaces
(18 holes)
9 holes at 50% of above
rates
5 l/t spaces per 9 holes
Golf driving range 1.5 spaces per tee 1 s/t space per 5 tees 1 in 10 active
provision
1 in 4 passive
provision
Other sports and
recreational uses
To be assessed on a site-by-site basis, dependent on
anticipated staffing, levels of use and numbers of paying
spectators
Sui Generis
Multi-screen cinemas
and theatres
1 space per 5 seats on free
standing development
1 s/t space per 20 seats
(up to 500 seats) 25s/t plus
1 l/t per 100 seats
(over 500 seats)
1 l/t space per 10 staff
1 in 5 spaces
active
provision
1 in 3 spaces
passive
provision
Hot food takeaways 2 spaces per 5m2 of public
floorspace
1 s/t per 100m2
1 l/t space per 10 staff
1 in 10
spaces active
provision
1 in 5 spaces
passive provision
(min requirement 5
spaces)
Drinking
establishments
1 space per 5 m2 of public
Floorspace
1 s/t space per 100 m2
1 l/t space per 10 staff
1 in 10 spaces active
provision
1 in 4 spaces
passive
provision
Motor Trade related (Sui Generis)
Staff 0.75 spaces per FTE staff
1 l/t space per 10 staff
1 in 5 spaces active
provision
1 in 3 spaces
passive
provision
Showroom and car
sales
1 space per 10 cars
displayed
1 in 10 spaces active
provision
1 in 5 spaces
passive
provision
Vehicle storage 1 space per showroom
or 10% of annual
turnover
1 in 5 spaces active
provision
1 in 3 spaces
passive
provision
Hire cars 1 space per 2 cars based
on
Site
1 in 5 spaces active
provision
Ancillary vehicle
storage
2 spaces or 75% of the
total if more than 3
vehicles
1 l/t space per 10 staff
Remaining
passive provision
3in 10 spaces active
3 in 10 spaces
passive
Workshops 3 spaces per bay 1 in 10 spaces active
provision
1 in 5 passive
provision (5 parking
spaces minimum)
Table 3 Car parking for disabled people
Use Class / Type Minimum Parking Standard
Employment Generating Development
Up to 25 parking spaces 2 disabled spaces
26 to 50 parking spaces 3 disabled spaces
51 to 75 parking spaces 4 disabled spaces
76 to 100 parking spaces 5 disabled spaces
Thereafter 1 disabled space for every 50 spaces or part
thereof
Shops / Buildings to which the public have access and Public Car Parks
Up to 20 parking spaces 2 disabled spaces
21 to 40 parking spaces 3 disabled spaces
40 to 60 parking spaces 4 disabled spaces
61 to 80 parking spaces 5 disabled spaces
81 to 100 parking spaces 6 disabled spaces
Thereafter 3 disabled spaces for every 100 spaces or part
thereof
Hotels As for employment generating development or 1
disabled space per room built to mobility
standards, whichever is the greater