From the plan

Appendix 7 Sustainable Parking Standards

On pages 684 to 690 of the official PDF.

The human version

This section is Appendix 7, which sets out sustainable parking standards. Table 1 gives residential standards for car parking, cycle storage and electric vehicle charging. For general needs housing, car parking starts at 0.5 spaces per studio unit, 0.75 per 1 bedroom unit and 1 per 2 bedroom unit, rising for larger homes. Long term cycle storage is 1 per bedroom for 1 to 3 bedrooms. Specialist housing and HMOs have their own standards. Table 2 sets non-residential standards, by use, for car parking, cycle parking and charging points.

An unofficial plain English summary. The official wording below is what counts at examination; check it before you rely on anything here.

Open PDF at p. 684

What the plan says

The text below is extracted automatically from the official PDF and may contain artefacts; the PDF is authoritative.

Appendix 7: Sustainable Parking Standards Table 1 Residential Parking Standards C3 – Residential units1 Car parking spaces Cycle storage spaces Charging Plug in Points General Needs Housing (including flats and bungalows) Curtilage Communal Studio 0.5 per unit 1 to 3 bedrooms: 1 per bedroom long term 4 or more bedrooms: 3 per unit long term 1 visitor space per 10 units short term 1 socket/charging point per house with private parking- Communal parking - 1 active charging point per dwelling unit Remaining spaces passive provision over and above 1 space per unit and above 10 units 1 bedroom 0.75 per unit 2 bedroom 1 per unit 3 bedroom (flat) 1.5 per unit 3 bedroom (house) 2 per unit 1.5 per unit 4 bedroom 2 per unit 5 bedroom To be determined on a case-by-case basis 6 + bedroom Additional parking requirements HMO 0.5 spaces per bed 1 per bedroom long term 1 socket/charging point per house with private parking or 1 roadside charging point per house where private parking is no available Houses with additional habitable rooms on upper floors/ roof space 1 per additional habitable room2 1 per bedroom long term Communal parking 1 in 3 active provisions Remaining spaces passive provision Flats or Bungalows with a total of 6 or more habitable rooms and bedrooms 1 All spaces to be rounded to the nearest whole number in the case of odd numbers (e.g. 1 x 5 bed HMO, 3 spaces, 3 x 1 bed flats, 2 spaces). For general needs housing, additional visitor parking in larger schemes with communal parking should not exceed 0.2 space per dwelling with 1 disabled visitor space for every 10 visitor spaces. 2 All rooms over 8 square metres which are not kitchens, utility rooms, bathrooms, WCs or circulation space are a habitable room. Large habitable rooms or open plan areas, typically over 25m2 and capable of subdivision will be treated as two habitable rooms. Parking requirements for additional habitable rooms on upper floors within townhouses or dwellings with reversed layouts will be considered on their individual merits but will not typically be sought unless there are three or more additional habitable rooms within the entire property. Houses with 5 or more habitable rooms on the ground or lower ground floor Specialist housing with support or care Category I – Retirement dwellings, no 24-hour warden control, 1 bedroom 1 per unit 1 per bedroom long term 1 socket/charging point per unit with private parking- 1 in 5 spaces active provision Remaining spaces passive provision 1 per 20 units short term visitor 1 per 20 bedrooms long term Category I – Retirement dwellings, no 24-hour warden control, 2 or more bedrooms 1 per unit Category II – Supported or extra care, self-contained units (with on-site staff), 1 bedroom . 0.75 per unit for residents and visitors, 0.25 per unit for staff Category II – Supported or extra care self-contained units (with on-site staff), 2 or more bedrooms 1 per unit for residents and visitors, 0.25 per unit for staff Category III – non- self-contained specialist housing including nursing or care homes To be determined on a case-by-case basis Table 2 Non-Residential Parking Standards3 Unless otherwise stated, floor areas are gross measured externally. Use Class / Type Required number of parking spaces (including visitor spaces unless otherwise stated) Minimum cycle parking standard Electric Vehicle Charging Points Class E Superstores Large supermarkets 1 space per 20m2 1 s/t space per 100m2 of floor space 1 l/t space per 200m of floorspace 1 in 10 spaces active provision 1 in 4 spaces passive provision Retail warehouses Garden centres Other retail uses 1 space per 35 m2 3 FTE = full time equivalent. s/t = short term. l/t = long term Parking requirements will be rounded up or down to the nearest whole parking space requirement (e.g. a B8 development of 350m2 would be expected to provide 11 car parking spaces, rather than 11.25 spaces). Financial and professional services (Banks, building societies etc.) 1 space per 40 m2 (Town centres) 1 space per 30 m2 (neighbourhood or local centres) 1 s/t space per 200 m2 1 l/t space per 200m2 1 in 10 spaces active provision 1 in 5 passive provision (minimum requirement- 5 spaces) Restaurants and Cafes 1 space per 5 m2 of public floorspace 1 s/t space per 100 m2 1 l/t space per 100m2 1 in 10 spaces active provision 1 in 4 spaces passive provision Offices 1 space per 40m2 1 s/t space per 500 m2 1 l/t space per 200m2 (Office) staff 1 l/t space per 500m2 (Industrial) 1 in 5 spaces active provision 1 in 2 spaces passive provision Researc h and Develop ment 1 space per 50 m2 Parking provision for lorries considered on a case-by- case basis Light industrial Film and Television Production 1 space per 50 m2 Parking provision for production trucks, trailers and other ‘on location’ vehicles will be considered on a case-by-case basis 1 l/t space per 200m2 and 1 s/t space per 1000m2 (for office accommodation and workshop schemes) 1 l/t space per 500m2 (for sound stages) 1 in 5 spaces active provision 1 in 2 spaces passive provision Day centres 1 space per 9 m2 or 1 space per 4 visitors plus 1 space per FTE staff 1 s/t space per 200m2 1 l/t space per 200m2 1 in 10 spaces active provision 1 in 4 spaces passive provision Surgeries and clinics (including doctors, dentists and vets) 1.5 spaces per consulting room 1 space per FTE non- consultant staff Greatest of: 1 per 50m2 or 1 per 30 seats/capacity 1 l/t space per 5 staff 1 in 10 spaces active provision 1 in 5 spaces passive provision Nursery schools / playgroups 1 space per 4 pupils 2 l/t space per 10 staff 1in 5 spaces active provision 1 in 3 spaces passive provision Class B2 General industrial up to 250 m2 floorspace 5 spaces plus 1 space per 50m2. Parking provision for lorries considered on a case-by-case basis 1 s/t space per 1000 m2 1 l/t space per 500m2 1 in 5 spaces active provision 1 in 2 passive provision General industrial over 250 m2 10 spaces plus 1 space per 75m2. Parking provision for lorries is considered on a case-by- case basis. Class B8 Storage or distribution up to 250 m2 floorspace 1 space per 75m2. Parking provision for lorries considered on a case-by- case basis 1 s/t space per 1000m2 1 l/t space per 500m2 1 in 5 spaces active provision 1 in 2 spaces passive provision Storage or distribution over 250 m2 floorspace 10 spaces plus 1 space per 75m2. Parking provision for lorries considered on a case-by- case basis Class C1 Hotels and motels5 1 space per bedroom plus 1 space per 3 FTE staff plus 1 space per 5 m2 public floor space for conference or exhibition facilities plus 1 coach space per 100 bedrooms (minimum) 1 l/t space per 10 beds 2 l/t space per 10 staff 1 in 5 active provisions Remaining spaces passive provision Small hostel (single parent or couple with no children) 0.75 spaces per unit 1 l/t space per 2 units 1 l/t space per unit Family hostel (two adults and two children) 1 space per unit Class C2 Institutions / homes with care staff on premises at all time1 Please see specialist housing requirements Supported or other specialist housing 1,2 Hospitals To be assessed on a case-by-case basis Education – Halls of Residence 1 space per 2 FTE staff plus 1 space per 6 students 1 l/t space per 3 students 1 l/t space per 10 staff 1 in 5 spaces active provision remaining spaces passive provision Class F1 Schools (including residential) 1 space per FTE staff plus 1 visitor space per 100 students Minimum requirement (based on travel plan mode share targets) 1 space per 10 students 1 space per 20 staff 1 in 5 spaces active provision 1 in 3 spaces passive provision Further education 1 space per FTE staff, plus 1 space per 5 full-time students 1 l/t space per 5 students 1 l/t space per 10 staff 1 in 5 spaces active provision 1 in 3 spaces passive provision Places of worship 1 space per 10 m2 Greatest of: 1 per 50m2 or 1 per 30 seats capacity 1 in 10 spaces active provision 1 in 4 spaces passive provision Public halls and places of assembly 1 space per 9 m2 or 1 space per 3 fixed seats plus 3 spaces per 4 FTE staff Greatest of: 1 per 50m2 or 1 per 30 seats capacity 1 in 10 spaces active provision 1 in 4 spaces passive provision Class F2 Community and family centres 1 space per 9 m2 plus 1 space per FTE staff Greatest of: 1 per 50m2 or 1 per 30 seats capacity 1 in 10 spaces active provision 1 in 4 spaces passive provision Squash courts 2 spaces per court 1 s/t space per 25 2 1 space per 10 staff Gyms and health clubs 1 space per 15 m2 public floorspace Ice rink 1 space per 12 m2 rink area Ten pin bowling 2 spaces per lane 1 s/t space per 3 lanes /rink 1 s/t space per 25 spectator seats 1 l/t space per 10 staff Football pitches 20 spaces per pitch 1 space per 5 paying spectators (where there is fixed or temporary seating) 2 s/t space per pitch 1 in 10 active provisions 1 in 4 passive provisions Other outdoor pitches 1 space per 2 users (maximum potential usage) 1 space per 5 paying spectators (where there is fixed or temporary seating) Golf course 100 spaces plus 50 overflow spaces (18 holes) 9 holes at 50% of above rates 5 l/t spaces per 9 holes Golf driving range 1.5 spaces per tee 1 s/t space per 5 tees 1 in 10 active provision 1 in 4 passive provision Other sports and recreational uses To be assessed on a site-by-site basis, dependent on anticipated staffing, levels of use and numbers of paying spectators Sui Generis Multi-screen cinemas and theatres 1 space per 5 seats on free standing development 1 s/t space per 20 seats (up to 500 seats) 25s/t plus 1 l/t per 100 seats (over 500 seats) 1 l/t space per 10 staff 1 in 5 spaces active provision 1 in 3 spaces passive provision Hot food takeaways 2 spaces per 5m2 of public floorspace 1 s/t per 100m2 1 l/t space per 10 staff 1 in 10 spaces active provision 1 in 5 spaces passive provision (min requirement 5 spaces) Drinking establishments 1 space per 5 m2 of public Floorspace 1 s/t space per 100 m2 1 l/t space per 10 staff 1 in 10 spaces active provision 1 in 4 spaces passive provision Motor Trade related (Sui Generis) Staff 0.75 spaces per FTE staff 1 l/t space per 10 staff 1 in 5 spaces active provision 1 in 3 spaces passive provision Showroom and car sales 1 space per 10 cars displayed 1 in 10 spaces active provision 1 in 5 spaces passive provision Vehicle storage 1 space per showroom or 10% of annual turnover 1 in 5 spaces active provision 1 in 3 spaces passive provision Hire cars 1 space per 2 cars based on Site 1 in 5 spaces active provision Ancillary vehicle storage 2 spaces or 75% of the total if more than 3 vehicles 1 l/t space per 10 staff Remaining passive provision 3in 10 spaces active 3 in 10 spaces passive Workshops 3 spaces per bay 1 in 10 spaces active provision 1 in 5 passive provision (5 parking spaces minimum) Table 3 Car parking for disabled people Use Class / Type Minimum Parking Standard Employment Generating Development Up to 25 parking spaces 2 disabled spaces 26 to 50 parking spaces 3 disabled spaces 51 to 75 parking spaces 4 disabled spaces 76 to 100 parking spaces 5 disabled spaces Thereafter 1 disabled space for every 50 spaces or part thereof Shops / Buildings to which the public have access and Public Car Parks Up to 20 parking spaces 2 disabled spaces 21 to 40 parking spaces 3 disabled spaces 40 to 60 parking spaces 4 disabled spaces 61 to 80 parking spaces 5 disabled spaces 81 to 100 parking spaces 6 disabled spaces Thereafter 3 disabled spaces for every 100 spaces or part thereof Hotels As for employment generating development or 1 disabled space per room built to mobility standards, whichever is the greater
Homes & housingJobs & economyTransport & travel
← Back to the plan search

Have your say

Tips for a response that counts

One focused page beats ten rambling ones. Read the full guide to consultations

  1. Submit a formal representation. This is the only response that must be considered at the plan’s independent examination. The emails below are worth sending too, but they do not count as representations. Open the official response portal

    This portal is one form for the whole plan, and it asks which policy or site allocation you are commenting on. Quote the policy reference and page numbers shown here in your answer so your point is logged against the right part.

    Write your comments before you open the portal: a notes app, an email draft or paper all work. Paste each one in and keep a copy. Ticking policies as you read builds the draft for you on the My response page.

  2. Email your ward councillors. They voted on this plan and represent you. The draft raises the consultation window and the missing costs.
    Not sure of your ward? Find your councillor →
  3. Email the planning policy team with questions about the consultation. Email the policy team

Deadline: 11:59pm, Thursday 19 November 2026. Emails open in your own mail app with a suggested draft. Edit it so it says what you think.