Policy DM5.5

Residential Standards

On pages 77 to 82 of the official PDF.

The human version

This policy, Policy DM5.5, sets minimum standards for new homes, including extensions. All units should meet or exceed the nationally described space standards in Policy Table DM5.5. For proposals of 10 or more dwellings, at least 20% must meet Building Regulation M4(2) for accessible and adaptable homes. A further 10% must be suitable for wheelchair users under M4(3). Every home should have usable private outdoor space, such as a garden or balcony, plus vehicle and cycle parking. The technical rules include a single bedroom of at least 7.5sqm, a double bedroom of at least 11.5sqm, and a ceiling height of at least 2.3m over 75% of the floor area.

An unofficial plain English summary. The official wording below is what counts at examination; check it before you rely on anything here.

Open PDF at p. 77

What the plan says

The text below is extracted automatically from the official PDF and may contain artefacts; the PDF is authoritative.

Policy DM5.5: Residential Standards 1. Planning applications for new residential development (including residential extensions and residential accommodation falling outside Use Class C3) must comply with the following requirements: i. all residential units should meet or exceed the nationally described space standards 1 (Policy Table DM5.5); ii. for proposals providing 10 or more dwellings, 20% of the residential units should as a minimum be accessible and adaptable in accordance with Building Regulation M4(2) 2, and a further 10% of the residential units should be suitable for occupation by a wheelchair user in accordance with Building Regulation M4(3) 3 and be evenly spread across both private and affordable tenure, size and type of dwelling. Where the Council is responsible for allocating or nominating the occupier, these homes should be ‘wheelchair accessible’ and preferably with ground floor access at the point of completion, whilst in other cases they may be ‘wheelchair adaptable’. Where this is not practicable on-site an equivalent financial contribution must be provided 4; and iii. make provision for usable private outdoor amenity space for the intended occupiers; for flatted schemes this could take the form of a balcony or easily accessible semi-private communal amenity space. Residential schemes with no amenity space will only be considered acceptable in exceptional circumstances, the reasons for which will need to be fully justified and clearly demonstrated; iv. make provision for vehicle and cycle parking, as appropriate (Policy DM10.3 and Appendix 9). Exceptions to the above criteria will only be permitted where the applicant has provided a robust justification, and the Council is satisfied that particular circumstances apply. 2. All proposals for non self-contained accommodation (such as student, hospital staff, some forms of older people accommodation) must as a minimum meet the nationally described space standards as set out in Policy Table DM5.5, with particular reference to room size set out in the technical requirements. 1 The nationally described space standards as set out in the policy or as amended. Residential accommodation that does not fall within a C3 use class (e.g. extra care accommodation, assisted living housing and Housing in Multiple Occupation) and residential extensions will be expected to meet the standards where relevant. As a minimum such accommodation should meet the standards for bedroom sizes, storage, ceiling heights and provision of level access. 2 Building Regulations M4(2) or as amended. 3 Building Regulations M4(3) or as amended. Policy Table DM5.5: Nationally Described Space Standards Minimum gross internal floor area and storage (sqm) Number of bedrooms (b) Number of bed spaces (persons) 1 storey dwellings 2 storey dwellings 3 storey dwellings Built-in storage 1b 1p 39 (37) * 1.0 2p 50 58 1.5 2b 3p 61 70 2.0 4p 70 79 3b 4p 74 84 90 2.5 5p 86 93 99 6p 95 102 108 4b 5p 90 97 103 3.5 6p 99 106 112 7p 108 115 121 8p 117 124 130 5b 6p 103 110 116 3.5 7p 112 119 125 8p 121 128 134 6b 7p 116 123 129 4.0 8p 125 132 138 Technical Requirements: i. the residential unit provides at least the gross internal floor area and built-in storage area set out in Policy Table DM5.5. ii. a residential unit with two or more bedspaces has at least one double (or twin) bedroom. iii. in order to provide one bedspace, a single bedroom has a floor area of at least 7.5sqm and is at least 2.15m wide. iv. in order to provide two bedspaces, a double (or twin bedroom) has a floor area of at least 11.5sqm. v. one double (or twin bedroom) is at least 2.75m wide and every other double (or twin) bedroom is at least 2.55m wide vi. any area with a headroom of less than 1.5m is not counted within the Gross Internal Area unless used solely for storage (if the area under the stairs is to be used for storage, assume a general floor area of 1sqm within the Gross Internal Area) vii. any other area that is used solely for storage and has a headroom of 900-1500mm (such as under eaves) is counted at 50% of its floor area, and any area lower than 900mm is not counted at all viii. a built-in wardrobe counts towards the Gross Internal Area and bedroom floor area requirements but should not reduce the effective width of the room below the minimum widths set out above. The built-in area in excess of 0.72sqm in a double bedroom and 0.36sqm in a single bedroom counts towards the built-in storage requirement ix. the minimum floor to ceiling height is 2.3m for at least 75% of the Gross Internal Area Notes: 1. Built-in storage areas are included within the overall GIAs and include an allowance of 0.5sqm for fixed services or equipment such as a hot water cylinder, boiler or heat exchanger. 2. GIAs for one storey dwellings include enough space for one bathroom and one additional WC (or shower room) in dwellings with 5 or more bedspaces. GIAs for two and three storey dwellings include enough space for one bathroom and one additional WC (or shower room). Additional sanitary facilities may be included without increasing the GIA provided that all aspects of the space standard have been met. 3. Where a 1b1p has a shower room instead of a bathroom, the floor area may be reduced from 39sqm to 37sqm as shown bracketed. 4. Furnished layouts are not required to demonstrate compliance. Houses in Multiple Occupation – development management policy Reference to Strategic Objective and Strategic Policies Strategic Objective 2 Strategic Objective 3 Strategic Objective 9 Strategic Objective 13 Strategic Policy SP5 Why we need this Policy (justification) 5.52 Houses in Multiple Occupation (HMOs) and other shared housing form part of the city’s private rented housing stock and make a contribution to people’s housing choice. With significant rises in the cost of housing over the past 20 years a growing number of people in Southend have turned to more affordable shared housing, including Houses in Multiple Occupation. 5.53 However, multiple occupancy has the potential to create negative impacts on the residential amenity and character of an area as a result of more frequent noise nuisance and disturbance, increased pressure on parking due to higher population densities, and higher levels of population transience leading to a possible longer-term breakdown of community cohesion. 5.54 As such HMOs are likely to have proportionately greater impacts on surrounding occupants and neighbourhoods as each additional resident will increase the level of activity through more frequent comings and goings, different patterns of behaviour and consequential noise and disturbance. A property occupied by a group of unconnected adults is likely to have a greater impact 48 See Topic Paper on HMO’s: https://localplan.southend.gov.uk/evidence-documents than a typical family home with a similar number of occupants as lifestyles and movement patterns will be less connected. 5.55 A House in Multiple Occupation is defined as a property rented to at least three people who are not from one ‘household’ (e.g. a family) but share facilities such as a bathroom and kitchen. Examples include bedsits, shared houses and lodgings. The planning Use Classes Order distinguishes between ‘small’ HMOs of up to six people (Use Class C4), and ‘large’ HMOs of seven of or more occupants which are sui generis. The General Permitted Development Order (GPDO) provides permitted development rights to convert ordinary family housing (Use Class C3) to small Class C4 HMO use without the need for planning approval. Larger sui generis HMOs on the other hand will always require planning approval to be created from either Class C3 housing or any other land use. To bring all HMOs under planning control it is proposed to introduce an Article 4 Direction in the city removing permitted development rights. 5.56 The number of HMO’s have been increasing in recent year 48. These are principally concentrated in Edwardian and Victorian housing in the central parts of the city in the Westcliff, Southend Central and Southchurch neighbourhoods. Of the remaining HMOs the majority are in the southern part of the Leigh neighbourhood. All these areas are characterised by tightly knit housing with limited off- street parking spaces, located near to city and district centres and transport hubs. 5.57 With growing numbers of people turning to HMOs as a source of affordable housing, the HMO policy seeks to ensure that an appropriate balance is struck between meeting the demand for this form of housing whilst protecting and safeguarding the character and amenities of established residential areas. The policy also seeks to provide good quality accommodation by ensuring development complies with relevant standards and requirements. Residential spaces and amenity standards are set out within Policy DM5.3, and DM10.3 (and Appendix 9) set out parking standards for different types of development. 5.58 In addition, the HMO policy recognises the need to safeguard an adequate stock of small family dwellinghouses to meet the demands for family housing in the city in accordance with the provisions of Policy DM5.4 and permits the reversion of HMO properties to family homes. How the Policy Works 5.59 This policy applies to building new HMOs; converting existing dwellings into HMOs; intensifying existing HMOs through an increase in the number of bedspaces, where this requires planning permission; and other forms of shared housing. 5.60 Policy DM6.6 (Houses in Multiple Occupation) responds to the demand for lower cost housing accommodation by allowing for further conversion to HMOs but only where this does not harm residential amenities and the character of an area or where the choice of housing is reduced and no longer provides for the different groups within the community through concentrations of HMOs. The Council considers that a harmful concentration is likely to arise when more than 10% of the total dwelling stock is occupied as HMOs within 50 metres of the site. Harm can also be localised when an existing dwelling is sandwiched between two HMOs intensifying impacts on individual households or where it results in a continuous frontage of three or more HMOs. 5.61 To ensure a good standard of accommodation for future occupiers, issues relating to internal living space, layout, external amenity space, outlook, privacy, adaptability, security, safety, cycle and car parking and refuse and recycling storage will need to be considered. All HMOs should meet the Essex HMO Amenity Standards (or subsequent equivalent document), which provide a guide to the minimum standards for amenities and space permitted in an HMO. 5.62 The Housing Act 2004 requires landlords of larger HMOs to apply for licences which is a separate regulatory regime to planning and seeks to secure minimum standards of accommodation fit for human habitation such as fire safety standards and access to basic facilities such as a kitchen, bathroom and toilet facilities. Regulatory standards also apply to smaller HMOs. The planning system has a wider responsibility for ensuring that the quality of accommodation will provide more than the bare minimum for its occupants by ensuring an adequate standard of living for long term occupants. 5.63 Where additional bedrooms are created in both new build HMOs and conversions of existing buildings, these will be expected to meet the internal space standards set out in Policy DM6.5. Appropriately sized, proportioned and equipped communal areas and adequate bathroom and cooking facilities should be provided, relative to the expected number of occupants in accordance with the Council’s adopted guidance. 5.64 Communal living space should be provided within the main structure of the building and not within conservatories due to the inferior noise insulation and consequent effect on amenity of neighbours. Insufficient communal areas increase the time occupants must spend in their individual bedrooms and can therefore hinder social cohesion within the property. 5.65 Planning applications must be supported by a full set of floor plans that includes details showing the internal measurements for each room; for bedrooms indicating if they are intended to be single or double; and any areas of reduced ceiling heights. 5.66 HMO proposals are also required to provide useable private outdoor amenity space appropriate to the scale and character of the development as required by Policy DM6.5: Residential Standards.
Design & placemakingHomes & housingTransport & travel📍 Leigh📍 Southchurch📍 Southend📍 Westcliff
← Back to the plan search

Have your say

Tips for a response that counts

One focused page beats ten rambling ones. Read the full guide to consultations

  1. Submit a formal representation. This is the only response that must be considered at the plan’s independent examination. The emails below are worth sending too, but they do not count as representations. Open the official response portal

    In the portal, open the chapter or policy you want to comment on and press Comment on that item. There is no single box for the whole plan, and you will need to create an account first.

    Write your comments before you open the portal: a notes app, an email draft or paper all work. Paste each one in and keep a copy. Ticking policies as you read builds the draft for you on the My response page.

  2. Email your ward councillors. They voted on this plan and represent you. The draft raises the consultation window and the missing costs.
  3. Email the planning policy team with questions about the consultation. Email the policy team

Deadline: 5pm, Monday 21 December 2026. Emails open in your own mail app with a suggested draft. Edit it so it says what you think.