This policy directs development to areas at the lowest risk of flooding from all sources, now and in future. The Sequential Test, and the Exception Test where required, must be applied. Where flood risk exists, the most vulnerable uses must go in the lowest risk parts of a site. Development must be safe for its lifetime, allow for climate change, not increase flood risk elsewhere and provide safe access and egress. A proportionate Flood Risk Assessment is needed where required. Schemes next to watercourses must keep an undeveloped buffer, and culverting is only supported where there is no practical alternative. Land for flood management infrastructure must be safeguarded.
An unofficial plain English summary. The official wording below is
what counts at examination; check it before you rely on anything here.
What the plan says
The text below is extracted automatically from the official PDF and may
contain artefacts; the PDF is authoritative.
Policy WAT2: Flood risk
1. Development must be directed to areas at the lowest risk of flooding from all sources, taking account
of current and future flood risk. The Sequential Test and where required, the Exception Test must be
applied in accordance with national policy.
2. Where flood risk is present, development must:
a. Apply a sequential approach in the site, locating the most vulnerable development in areas of
lowest flood risk.
b. Be safe for its lifetime, taking account of climate change and the vulnerability of its people.
c. Not increase flood risk elsewhere and where practical, reduce flood risk on and beyond the site.
d. Preserve flood storage, overland flow routes and other features which contribute to flood risk
management unless suitable mitigation is secured.
e. Provide safe access, egress and emergency arrangements where required.
Flood risk assessment and mitigation
3. Development must be supported by a proportionate Flood Risk Assessment where required by
national policy, relevant evidence or site circumstances. Assessments must consider all sources of
flood risk, climate change, residual risk and cumulative impacts.
4. Development should incorporate appropriate flood resilience and resistance measures and maximise
opportunities for natural flood management and multifunctional blue-green infrastructure.
Watercourses and flood management infrastructure
5. Development adjacent to watercourses must retain an appropriate undeveloped buffer and safeguard
their flood management, ecological and maintenance functions.
6. The culverting of watercourses will only be supported where it is demonstrated to be necessary and
there is no reasonably practical alternative.
7. Development must safeguard land required for existing or planned flood management infrastructure,
flood storage areas or natural flood management measures and must not prejudice their operation or
future delivery.
Surface water and sustainable urban drainage systems
9.14 Sustainable urban drainage systems (SuDs) are central to the management of surface water. SuDS should
mimic natural drainage processes and manage rainfall close to where it falls. Their role extends beyond
controlling runoff. Well-designed systems can improve water quality, provide habitat, support biodiversity,
enhance landscape and open space, provide urban cooling and contribute to attractive blue-green
infrastructure. They must be integrated into the layout of development rather than treated as residual
engineering infrastructure.
9.15 The drainage hierarchy prioritises the capture and reuse of rainfall before infiltration or discharge from
a site. This approach reduces demand for potable water while reducing the volume of runoff entering
watercourses and drainage networks. Care will be required where infiltration is proposed in Groundwater
Source Protection Zones or other areas where groundwater is vulnerable to pollution.
9.16 Surface water should be managed as close to its source as practical and development should follow the
drainage hierarchy when considering disposal options. Infiltration is generally the preferred approach
where ground conditions are suitable and there would be no unacceptable risks to groundwater quality,
land stability or other environmental interests. Where infiltration is not appropriate, applicants should
demonstrate higher-order options in the hierarchy have been properly considered before reliance is placed
on piped systems or sewer networks.
9.17 Surface water management should ensure development does not increase flood risk either onsite or
elsewhere. Drainage systems should be designed to accommodate appropriate climate change allowances,
manage exceedance flows safely and achieve runoff rates and volumes that are consistent with the
requirements of the Lead Local Flood Authority and relevant national and local guidance. Development on
previously developed land should seek opportunities to reduce existing runoff rates wherever practical.
9.18 Above-ground and nature-based drainage features are generally preferable to below-ground engineered
solutions because they can provide multiple benefits for biodiversity, amenity, water quality, climate
resilience and placemaking. SuDS should be integrated with green infrastructure, open space, landscaping
and ecological enhancement wherever practical.
9.19 Major and phased developments should be supported by a comprehensive drainage strategy demonstrating
how surface water will be managed across the whole site. Drainage proposals should not prejudice the
effective drainage of later phases of development or adjoining land and should be designed so they can
function as part of an integrated drainage network.
9.20 Effective arrangements for the long-term management, maintenance and funding of drainage infrastructure
are essential to ensure systems continue to operate as intended throughout the lifetime of the development.
Applicants should demonstrate how drainage features will be maintained and by whom.