The human version (we wrote this, not the council)
This policy supports the University of Northampton at its Waterside Campus. The site is safeguarded for education and ancillary uses, and development should improve links with the wider Central Area. The Council will continue to support student accommodation and related uses. Proposals should respond to the riverside setting and green and blue infrastructure, and address flood risk, drainage and utility constraints. A site-specific Flood Risk Assessment is needed, meeting the Upper Nene design standard of a 0.5% probability event plus climate change allowance. Access for maintaining foul drainage infrastructure must be safeguarded.
An unofficial plain English summary. The official wording below is
what counts at examination; check it before you rely on anything here.
What the plan says
The text below is extracted automatically from the official PDF and may
contain artefacts; the PDF is authoritative.
Policy N5 – Northampton, University of Northampton Waterside Campus
A. The role and contribution of the University of Northampton will be supported through the
safeguarding of the site for education and ancillary uses which are required to serve the
role and function of the University. Future development proposals should seek to
enhance links between existing University facilities and the wider Northampton Central
Area infrastructure, supporting the University’s integration within the town, including
through improved connectivity, and in accordance with the other relevant requirements
of this Plan.
B. The Council will continue to support student accommodation and other relevant uses to
meet the needs of existing and future students, staff, visitors and investors.
C. Development proposals should respond positively to the site's riverside setting and green
and blue infrastructure network and demonstrate that flood risk, drainage and utility
infrastructure constraints have been appropriately addressed in accordance with relevant
Development Plan policies.
D. Proposals for this site should be accompanied by a site-specific Flood Risk Assessment
meeting the design standard for the Upper Nene catchment through Northampton of a
0.5% probability (1 in 200 chance of occurring in any given year) event plus an allowance
for climate change to protect against fluvial flooding. Surface water attenuation should be
provided up to this standard.
Any proposal should include the safeguarding of suitable access for the maintenance of foul
drainage infrastructure.
WNLP Objectives: 6, 7, 10, 11, 12, 14, 15
5.5. Provision for homes
5.5.1. A proportion of Northampton’s new housing in the plan period will be met by
planning permissions and allocations in existing adopted plans (the WNJCS and the
Northampton Part 2 plan). These include the allocations for the Sustainable Urban
Extensions.
5.5.2. A number of those allocated sites do not yet have the benefit of planning
permission. Because of their limited scale, it is not the intention to re-allocate any
of the sites with a capacity of less than 50 units in this Plan, therefore, any of
those sites that have not come forward after this Plan is adopted would be judged
against the relevant policies in this Plan. Sites of more than 50 units are re-
allocated in this Plan to provide certainty.
5.5.3. The spatial strategy prioritises regeneration and the use of brownfield sites within
Northampton’s Central Area. Local evidence, including the Central Area
assessment, identifies more capacity for residential developments within the
Central Area. Policy N3 addresses such regeneration needs by allocating
regeneration sites.
5.5.4. There are three allocations for Sustainable Urban Extensions in the WNJCS which
do not yet have the benefit of planning permission in whole or in part:
• Northampton North, allocated as N3 in the WNJCS, does not yet have
planning permission for its northern part. An outline application has the
benefit of a resolution to grant permission subject to the completion of a
section 106 agreement. The southern part has permission and is under
construction.
• Northampton West, allocated as N4 in the WNJCS, does not yet have
planning permission for its southern part. The northern part has
permission and is under construction.
• Northampton Upton Lodge, allocated as N9A in the WNJCS, does not yet
have planning permission for its eastern part. An outline application has
the benefit of a resolution to grant permission subject to the completion
of a section 106 agreement. The western part of the allocation (Norwood
Farm) has permission and is under construction.
5.5.5. To provide certainty, two of these sites are re-allocated in this plan as follows:
• Northampton North - the northern part of Northampton North is re-allocated. It
is proposed to extend this to the north and retitle as Land East of the A43.
• Northampton West – the remaining part to the south of Roman Road is re-
allocated in this Plan.
5.5.6. Northampton Upton Lodge has a resolution to grant, and permission is expected to
be issued imminently, it is therefore not necessary to re-allocate this site.
5.5.7. Not all of the housing requirement for the plan period can be met through existing
commitments and the regeneration sites. Further opportunities have been
identified as follows:
• East of Wooldale Road
• North of Newport Pagnell Road
• Land West of the A43
• Land East of the A43 (extension of Northampton North)
• North of Buckton Fields
• South of Grange Park
• Land off Harlestone Road
These are set out in policy N6.